Conference phones for every situation  
4
Description  
Top  
Green/red  
mic indicators  
Microphone  
Loudspeakers  
Keypad  
Bottom  
Telephone  
line input  
(POTS)  
Power supply  
Keyset  
OK key  
Up/Down key  
Conference  
key  
Mute/Pause key  
R key  
Redial key  
Konftel 100 • User Guide  
5
Description  
Connection  
240 V  
mains outlet  
Analogue  
telephone line  
(POTS)  
Mains  
trans-  
former  
Only a mains transformer  
of the FRIWO type  
FW7237/12 or the Perfekt  
2042, 2043, Helms-  
Man DEN4824129,  
ML120P070G,  
ED4824120070P and  
DBN4824129 (UK) type  
may be connected.  
2 PIN (-)  
3 PIN (-)  
4 PIN (+)  
5 PIN (+)  
Power supply  
and analogue  
POTS  
network  
cable, 7.5 m.  
Connectors  
underneath  
Konftel 100  
Accessories  
Spare parts  
Item No. Description  
Item No. Description  
9146030 Wall mounting bracket  
149110 Ceiling mount suspen-  
sion with cables  
900103334 Power supply and  
analogue POTS  
network cable, 7.5 m  
826102026 Mains transformer  
12 V DC for UK  
900103339 Extension cable, power  
supply 10 m  
900102026 Mains transformer  
12 V DC for Europe  
900103340  
Extension cable,  
analogue network, 10 m  
900103341  
Extension cable, power  
and analogue network  
7.5 m  
Konftel 100 • User Guide  
6
Calling  
Incoming calls  
A ring signal is heard and the green mic  
indicators light to indicate the incoming call.  
Press the OK key to answer.  
To end the call, press OK.  
Outgoing calls  
Press OK.  
Dial the number.  
0–9...  
To end the call, press OK.  
Redial  
Press the Redial key. The last number dialled  
within 3 sec.  
To end the call, press OK.  
Multi-party calls  
Press OK.  
0–9...  
0–9...  
Enter the number of the first meeting participant.  
When the first call is connected, press the  
R key to get a new dial tone.  
Enter the number of the second meeting  
participant and wait for answer.  
Press the R key followed by the 3 key, and all three can  
now participate in the call.  
Konftel 100 • User Guide  
7
Calling  
If your multi-party call is not answered  
Press the R key followed by the 1 key to  
return to the first call.  
Note: The availability and function of the multi-party feature can vary from  
country to country but also depend on the PBX to which the Konftel 100 is  
connected. If you want to connect multiple participants we recommend you use  
a telephone meeting service. If you have questions regarding availability, please  
contact your dealer.  
If the R key does not work  
The requirements for the operation of the R key vary between PBXs and from  
country to country. Konftel 100 therefore lets you program the R-pulse time so  
that it works with most PBXs on the market.  
Programming the R key (default setting = 2)  
Hold down the R key for three seconds until the green  
LEDs flash and you hear three short beeps.  
1–6...  
Enter the value for the R-pulse. The default setting is 2.  
Check in the table below whether the setting is right for  
your PBX/country.  
Value:  
Time:  
65 ms  
100 ms  
150 ms  
270 ms  
600 ms  
80 ms  
1 - R function  
2 - R function  
3 - R function  
4 - R function  
5 - R function  
6 - R function  
Press the OK key to save the setting and exit.  
Konftel 100 • User Guide  
8
Conference key  
The Conference key gives you the facility to pre-programme a  
number or code for your phone conference.  
Programming the Conference key  
Keep the Conference key depressed 3 sec until  
the red LEDs flash and you hear a repeating tone.  
Enter your phone conference number with the  
keypad (max 20 digits).  
0–9...  
If Konftel 100 must wait for a second dial  
tone, you should insert a pause with the Mute/  
Pause key.  
Press the OK to end and save the number.  
Using the Conference key  
Press the conference key to connect  
to your phone conference.  
Press OK to end the call.  
Delete the conference number  
Keep the Conference key depressed 3 sec until the  
red LEDs flash and you hear a repeating tone.  
Press OK to delete any conference number.  
Konftel 100 • User Guide  
9
Volume control, mute,  
tuning, ring signal volume  
Volume control  
Adjust the speaker volume with the Up/Down  
key during the call.  
Mute function  
Press the Mute key to switch off the micro-  
phone. The mic indicators change to red.  
Press again to switch on the microphone.  
The mic indicators change back to green.  
Tuning  
The sound is adjusted automatically for the  
room and the telephone line when Konftel  
100 is switched on. Konftel 100 senses the  
acoustics of the room and adapts continuously  
during the call. For manual tuning, press the  
Up/Down key at the same time. A brief noise  
will be heard.  
Adjust the ring signal volume  
Adjust the volume of the ring signal with the  
up/down button. A ringing signal is heard after  
every press. It can be adjusted in six steps,  
of which the lowest shuts off the ring signal  
entirely.  
Konftel 100 • User Guide  
10  
Troubleshooting  
and maintenance  
Troubleshooting  
1. Check that the microphone is on during the call.  
The green microphone indicators must be lit.  
2. Check that the Konftel 100 is connected to an  
analogue telephone jack.  
3. Bypass any extension cables and check whether  
the system is functioning correctly. If not,  
contact your dealer.  
4. If Konftel 100 must wait for a second dialling  
tone, you should enter a pause with the help of  
the pause/mute button when you programme the  
number for your phone conference.  
Maintenance  
Clean the equipment with a dry, soft cleaning cloth.  
Do not use any liquids!  
Konftel 100 • User Guide  
11  
Technical data  
Konftel 100  
Mains transformer (Europe): DC transformer 240 V AC/12 V DC; 700 mA.  
Mains transformer (UK):  
DC transformer 100 - 240 V AC/12 V DC; 700 mA.  
Network interface:  
Analogue PBX or PSTN, RJ-11.  
Power supply and  
network cable:  
7.5 metre, RJ-11 (line), EIAJ Class IV (power).  
Recommended room  
conditions:  
Reverberation time: <0.5 sec.  
Background noise: <45 dB(A).  
Frequency response:  
Loudspeaker volume:  
Room echo suppression:  
Line echo suppression:  
Automatic calibration:  
Dimensions:  
200 – 3700 Hz.  
85 dB SPL.  
208 ms.  
25 ms.  
<1 ms impulse (not discernible).  
Diameter 232 mm.  
700 g.  
Weight:  
Temperature range:  
Humidity:  
5 – 40° C in operation.  
20 % – 80 % non-condensing.  
EMC:  
EN 50 081-1:1992.  
EN 55024:1998.  
EN 60950.  
Electrical safety:  
Telecom approval:  
Keyboard:  
EN 60950.  
EUROPEAN TBR21.  
19 keys.  
Compatibility:  
Konftel 100 can be connected to any PBX equipped  
with a POTS extension, for example Ericsson: MD110,  
Fenix. Siemens: Hicom. Nortel: Meridan. Philips:  
Sopho. Alcatel: 4200, 4400. Ascom: Ascotel.  
Konftel 100 • User Guide  
Konftel is a leading company within speaker communication and audio technology. We  
develop and sell products and technology for telephone meetings based on cutting-edge  
expertise within acoustics and digital signal processing. Characteristic of our products is  
that all conference telephones contain the same high quality audio technology – Omni-  
Sound® – providing crystal clear sound. Read more about Konftel and our other products on  
Developed by Konftel AB  
Box 268, SE-901 06 Umeå, Sweden  
Phone: +46 90 706 489 Fax: +46 90 131 435  
3107-61-001 rev D  

JVC AV 29QT4SU User Manual
KitchenAid KEBS107Y User Manual
LG Electronics LG Life Good Computer Monitor E2441V User Manual
Maytag 8101P668 60 User Manual
Micro Innovations WJ HD220 User Manual
Moffat RN8403E LS User Manual
Omega Speaker Systems DPiTH i32 User Manual
Panasonic CT 13R38S User Manual
Philips 190B7 User Manual
Philips DMR EH60 User Manual