FBP Series Fluorescent Emergency Ballast
FBP50
Page 1 of 1
One or Two Lamp Operation 1,400 Lumens
The FBP Series quickly converts standard fluorescent luminaires into emergency luminaires.
13.3”
(33.9 cm)
1.5”
(3.8 cm)
2.4”
Nickel Cadmium Battery
(6.1 cm)
Complete Fixture consists of ballast unit. Select options and accessories below.
Model #
FBP50
Max. Lumens
1,400
Lamp Operation
One or Two
Lamp Operation and Performance (continued)
Features
1. Lamp Operation: Operates the following lamp types: T8 linear fluorescent,
T12 linear fluorescent, T9 circline, T12 U-bent, T5 long compact fluorescent,
compact 4-pin fluorescent. See Lamp Operation and Performance table for
specific lamp performance and operation.
Non-Emer.
Max.
Emer. Op.
Max.
Lumen
Emer.
Lamp
Lamp
Type
F96T12HO
F48T12
F17T8
Base
Type
Lumen
Output
8000
Watt.
95
Output
Operation
One
R17D/Recessed
R17D/Recessed
G13/Med Bi-Pin
G13/Med Bi-Pin
G13/Med Bi-Pin
G13/Med Bi-Pin
G13/Med Bi-Pin
FA8/Single-Pin
2G11/4--Pin
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1000
2. Illumination: Provides 90 minutes of emergency illumination, and produces
a maximum of 1,100 to 1,400 lumens initial emergency light output. Can be
used with most 17w to 215w (2’ - 8’) T8, T10 or T12 fluorescent lamps with-
out integral starters including U-shaped, HO, VHO, circline, energy saving,
and 4 pin compacts. It is also compatible with most 1, 2, 3 and 4-lamp elec-
tronic, standard, energy saving and dimming AC ballasts.
3. Housing: Constructed of 20 gauge steel with a high temperature powder
coat paint finish. Slim housing allows for wireway channel mounting on most
recessed luminaires.
4. Electronics: 120/277 VAC dual voltage input with surge-protected, solid-
state circuitry. Charging system is complete with AC indicator lamp and test
switch.
5. Battery: Maintenance free, sealed nickel cadmium battery has an estimated
service life of 10 years, and an operating temperature range of 32°F (0°C) to
131°F (55°C).
110
17
6200
One
1325
One or Two
One or Two
One or Two
One or Two
One
F25T8
25
2080
F32T8
32
2850
F32T8/U
F40T8
32
2700
40
3600
F96T8
59
5800
One
F27BX
27
1800
Two
F282D
28
GR10Q-4/4 Pin
GR10Q-4/4 Pin
2G11/4--Pin
2050
1100
One or Two
One or Two
One or Two
One
F382D
38
2850
1000
F39/36BX
F40/30BX
F50BX/FT55
F96T12HO
F96T12VHO
39
2850
1100
40
2G11/4--Pin
3150
1100
50-55
95
2G11/4--Pin
4300-4800
8000
1100
One or Two
One
R17D/Recessed
R17D/Recessed
1100 - 1400
1100 - 1400
95
8000
One
6. Input Power Requirements: 4 watts max.
7. Warranty: Electronics: 5 years; Battery: 5 years.
Notes:
1. Maximum non-emergency lumen output can vary based on lamp manufacturer, ambient
operating temperature, and ballast manufacturer.
Code Compliance
2. Maximum emergency lumen output is based on total output of one or two lamps, and can
vary based on lamp manufacturer and ambient operating temperature.
3. Maximum emergency lumen output is supported for a full 90 minutes of operation.
4. Consult factory for compatibility, operation and performance of lamp types not listed.
UL 924 listed, damp location listing optional.
UL listed for use within sealed and/or gasketed luminaires.
Options
EX = Special Input Transformer for 220 VAC/50 Hz, 240 VAC/50Hz.
Contact factory for other input voltages and frequencies.
DL = UL Damp Location Listing
Accessories
CCAPS = Wire bundle cover for mounting external to luminaire.
RTS = Single gang aluminum faceplate pre-drilled to accommodate remote
installation of test switch and pilot light.
Lamp Operation and Performance
Non-Emer. Emer. Op.
Job Information
Type:
Max.
Lumen
Output
1275
Max.
Lumen
Output
Emer.
Lamp
Operation
One or Two
One or Two
One or Two
One or Two
One or Two
One
Job Name:
Cat. No.:
Lamp
Type
Base
Type
Watt.
20
30
40
40
40
50
55
75
35
45
60
75
F20T12
G13/Med Bi-Pin
G13/Med Bi-Pin
G13/Med Bi-Pin
G13/Med Bi-Pin
FA8/Single-Pin
FA8/Single-Pin
FA8/Single-Pin
FA8/Single-Pin
R17D/Recessed
R17D/Recessed
R17D/Recessed
R17D/Recessed
R17D/Recessed
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
1100 - 1400
F30T12
F40T12
F40T12/U
F48T12
F60T12
2350
2650
3100
2875
Lamp(s):
Notes:
3600
4500
5500
1620
F72T12
F96T12
One
One
One
One
One
One
One
F24T12HO
F36T12HO
F48T12HO
F60T12HO
F72T12HO
2800
5150
4050
6350
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
85
Lightolier is a Philips group brand
|