Calculite® HID Downlight C7E17VM
Page 1 of 2
7" Aperture, ED17 (Enclosed), Ceramic Metal Halide, Medium Beam
20" (508 mm) to 30" (762 mm)
8-1/4"
9-3/4"
(210 mm)
(248 mm)
Flangless Trim with
Top View
(Magnetic Ballast)
9-7/8"
(251 mm)
Vertical Adjustment:
5/8" (16 mm) to
2 7/8" (73 mm)
20" (508 mm) to
30" (762 mm)
9-3/4"
(248 mm)
11" (280 mm)
(100/150W)
Top View
(Electronic Ballast)
7-3/8" (187 mm) Dia.
8-5/8" (200 mm) Dia.
2" (50 mm) max.
Ceiling Thickness
Ceiling Cutout: 8" (203mm) Dia.
Reflector Trim
Frame-In Kit
Lamp (Coated, Ceramic MH)
C770MHE1 Electronic 120V
C770MHE2 Electronic 277V
C710MHE1 Electronic 120V
C710MHE2 Electronic 277V
70W ED17, BD17 (Enclosed)
70W ED17, BD17 (Enclosed)
100W ED17, BD17 (Enclosed)
100W ED17, BD17 (Enclosed)
C7E17VM CLW
Specular Clear, White Painted Flange.
Specular Clear, Matching Flange.
CLP
CCDW
Comfort Clear Diffuse, White Painted Flange.
Comfort Clear Diffuse, Matching Flange.
Champagne Bronze, White Painted Flange.
Champagne Bronze, Matching Flange.
CCDP
CCZW
CCZP
C770MHU Magnetic 120V/277V 70W ED17, BD17 (Enclosed)
C710MHU Magnetic 120V/277V 100W ED17, BD17 (Enclosed)
Features
Electrical (cont)
1. Reflector Trim: Clear anodized aluminum, 0.040” (16-ga.). Provides Medium
beam distribution; 50° visual cut-off to lamp and lamp image; self-flange in
painted white or polished to match cone interior. Consult factory for other
finishes.
Ballast
ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 0.67/0.28
100W MH M90/M140 120/277 0.90/0.43
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,
HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting
temperature, Type 1 Outdoor rating.
78
110
2. Lamp Guard: High heat resistant glass (as required by code).
3. Socket Cup: Galvanized steel, pre-wired with medium base pulse rated
socket. Snaps onto upper reflector for secure attachment without tools;
assures proper lamp alignment to optics for consistent performance.
4. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed
mounting bars.
6. Retention Springs: Rust resistant springs secure reflector in place for quick,
tool-less installation.
7. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism
accommodates mounting to virtually any ceiling system using pre-installed
mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures
all adjustments. Alignment holes and markings allow fixture to be pre-set
prior to installation.
8. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30"
long and lock securely into position. Built-in locking tabs provide positive
attachment to common T-bar systems. Self-centering feature simplifies instal-
lation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
Ballast
ANSI Code Voltage Max. Amps Input Watts
70W MH M98/143
100W MH M90/140
120/277 1.90/0.80
120/277 2.40/1.10
94
125
Options and Accessories
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“.
Emergency Lamp: Add suffix E to Reflector Trim and Frame-In Kit. See Spec.
Sheet “E”.
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast): Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V)
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA (magnetic ballast only), I.B.E.W.
For 100W electronic, install fixtures with minimum spacing: 2 feet from
center-to-center of adjacent luminaries; 1/2 inch from top of luminaire to over-
head building member;1 foot from luminaire center to side building member.
Job Information
Type:
9. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V).
Accessible from below for inspection and/or replacement without tools.
10.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors; allows inspection from below.
11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Job Name:
Cat. No.:
Lamp(s):
Notes:
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.
<15%, thermally and transient protected, RMI / RFI complies with FCC Part 18
non-consumer equipment, shut-down circuit at end of lamp life, sound rating
"A", -5°F minimum starting temperature, Type 1 outdoor rating.
Lightolier a Genlyte Thomas Company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
|